We use cookies to ensure that we give you the best experience on our website.
PEPLINK · BRIEFLY EXPLAINED
What does SpeedFusion do?
SpeedFusion uses several suitable internet connections within a shared VPN tunnel. The three functions serve different purposes:
Bandwidth Bonding – use the bandwidth of multiple WAN connections for a shared data stream.
WAN Smoothing – send redundant packets to reduce the effects of packet loss and jitter. This requires additional bandwidth.
Hot Failover – preserve ongoing sessions through the remaining tunnel paths when a connection fails.
This requires compatible routers, a reachable endpoint, suitable WAN connections and the required features or licences. Uninterrupted availability is not guaranteed.
Definition and methodological approach:
IT-Grundschutz, developed by Germany’s Federal Office for Information Security (BSI), is a systematic methodology for establishing and operating an information security management system (ISMS). BSI Standard 200-1 describes the requirements for an ISMS, 200-2 the IT-Grundschutz methodology with Basic, Core and Standard Protection, and 200-3 supplementary risk analysis. The IT-Grundschutz Compendium contains building blocks with security requirements for organisation, infrastructure, networks, IT systems and applications; associated implementation guidelines explain possible safeguards. Standard Protection begins by defining the scope of the information domain and analysing its structure, followed by determining protection requirements. Appropriate building blocks are then assigned, and an IT-Grundschutz Check compares existing safeguards with the requirements. High or very high protection requirements, missing building blocks or atypical deployment scenarios call for supplementary risk analysis. The results inform safeguards, responsibilities and regular reviews. IT-Grundschutz is compatible with ISO/IEC 27001 and is not limited to critical infrastructure.
Relevance to critical infrastructure resilience:
IT-Grundschutz can help operators of critical installations develop a structured approach to information security. Legal requirements nevertheless arise from the applicable regulatory framework, not from a building block number alone. Germany’s BSI Act (BSIG) sets out risk management measures in sections 30 and 31, the reporting of significant security incidents in section 32, and evidence requirements for operators of critical installations in section 39; sector-specific exemptions must be checked. The relevant Compendium building block for routers and switches is NET.3.1, not NET.3.2 (Firewall). To support the security objective of availability, a redundant internet connection with WAN paths that are as independent of one another as possible may be useful. Its suitability depends on protection requirements, common causes of failure, power supply, and operational and emergency planning. WAN redundancy alone demonstrates neither full IT-Grundschutz conformity nor compliance with all statutory obligations.
Technical implementation and evidence:
Depending on the location, connection planning can combine terrestrial fibre, mobile networks and LEO satellite technology such as Starlink. Peplink Multi-WAN and bonding can contribute to availability when suitable WAN paths, power supply, configuration and, where required, a reachable bonding endpoint are in place. The service plan, required features and service scope must suit the deployment; wirelessmaxx offers Starlink terminals only together with a service plan and service. Monitoring and documented failure tests can support availability assessments. The scope and retention of logs depend on configuration and operation. Technical monitoring does not replace independent testing or certification. Section 39 BSIG generally requires the operators covered by that provision to submit evidence every three years through security audits, inspections or certifications; transitional provisions, exemptions and the deadline communicated by the BSI must be considered separately.
Critical infrastructure categories and distinctions: Who is affected?
Information current as of 6 November 2026. The term critical infrastructure (KRITIS) describes supply structures that are important to society. An organisation’s statutory obligations must be assessed separately, taking account of its activities, entity type and, where applicable, size or installation thresholds. The BSI Act and the Critical Infrastructure Umbrella Act have different priorities; a connectivity solution alone does not establish legal compliance.
1. Critical infrastructure sectors
The strategic overview of critical infrastructure sectors is not the same as the statutory scope. For the BSIG, section 28 and the entity types in Annexes 1 and 2 are particularly relevant. Section 4 of the Critical Infrastructure Umbrella Act defines its sectors, including energy, water, healthcare and space, and provides sector-specific exemptions. Federal administration entities are regulated separately under the BSIG. The blanket statement that government and public administration are exempt from the BSIG is therefore incorrect.
2. Critical installation operators and thresholds
Classification as an operator of a critical installation depends on the critical service, installation category and applicable thresholds or determinations by the competent authorities. The BSI Critical Infrastructure Ordinance, the transitional provisions in section 66 BSIG, and sections 4 and 5 of the Critical Infrastructure Umbrella Act together with the associated ordinances must be considered. A location label alone does not determine whether an organisation is in scope. Regardless of whether a critical installation threshold is exceeded, an organisation may qualify as an essential or important entity under section 28 BSIG; special cases and sector-specific exemptions must be assessed separately.
3. NIS2 Implementation Act vs. Critical Infrastructure Umbrella Act
The revised BSIG implementing the NIS2 Directive has applied since 6 December 2025. The Critical Infrastructure Umbrella Act entered into force on 17 March 2026. Their obligations and application dates should be considered separately:
NIS2 Implementation Act: Implements the European NIS2 Directive in Germany. The BSIG distinguishes between essential entities and important entities. Entity type, size criteria and statutory special cases are decisive, not simply classification as a large or medium-sized business. The focus is on cybersecurity and information security, including business continuity and availability.
Critical Infrastructure Umbrella Act: Strengthens the physical resilience of critical installations, for example against natural events and sabotage. Its own scope determines which operators are covered and which exemptions apply. Section 8 provides for registration details to be submitted to the BBK through a registration facility established jointly with the BSI. Applicable procedures, transitional provisions and deadlines must be checked against official information; this does not imply a blanket requirement for duplicate registration. A mobile communications solution does not fulfil the entire statutory resilience mandate.
Division of responsibilities: wirelessmaxx and Hypria
The division of company and service responsibilities is independent of statutory scope: wirelessmaxx addresses preventive connectivity and resilience needs, for example in hospitals, utilities and the energy sector. Its sister company Hypria is intended for deployment-related needs of fire services, Germany’s Federal Agency for Technical Relief (THW), and other relief and emergency response organisations. Terms such as “preventive” or “secondary KRITIS” describe only this internal division, not official sectors, a statutory protection hierarchy or a lesser importance of emergency response organisations.
wirelessmaxx – preparedness and connection planning: Internet connectivity is advised on and marketed under connecting.works GO . The suitability of fibre, mobile networks, satellite or a combination is assessed against applications, existing connections and deployment conditions. Redundancy and bonding are possible technical contributions to availability, not blanket proof of conformity or freedom from outages.
Hypria – operational communications: For incident sites, vehicles and temporary command or remote facilities, the focus is on communications and fallback concepts tailored to the requirements. Their design depends on the situation, power supply, available transmission paths and required services. They complement existing communications systems and organisational emergency planning rather than replacing them.
The right network solution for your project?
The Connection advice with connecting.works GO starts with your needs; connectivity, integration and support are coordinated as a solution. Purchasing a Peplink router in the eStore remains a separate route for specific hardware requirements.
Technology outlook: Hybrid architectures can reduce dependence on individual connection paths. The article on
Dynamic Weighted Bonding & Latency Mitigation
explores the technical management of multiple WAN paths. Achievable availability still depends on active connections, a suitable endpoint, power supply, configuration, service plans and operational planning; complete freedom from outages cannot be inferred from this. For mobile incident sites and temporary remote facilities, Hypria plans communications and fallback concepts according to the deployment requirements.